<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-09 21-59-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 74 dBuV MPB R2
Pilot RDS Phase Difference
11.0 kHz 6.1 kHz 16 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 68 kHz 18675 37,2369
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 3,93 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" MPB R2 " 2492 12 (Easy M) 1 0 1 1 22:03, 9.08.2025
RT
"Blaque - 808 "
AF EON
104.2 MHz -
FM Scope Max at: 68 kHz MIN: 17 kHz % above 76 kHz: 37,2369 Acquired: 2025/08/09 21.58.35 Total samples: 18675 Equivalent time: 0:15:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 4,7 dBr MIN: 3,1 dBr AVE: 3,93 dBr % above 12,2 dBr: 0,0 Last value: 3,9 dBr (2025/08/09 21.58.34) 21.44 21.46 21.48 21.50 21.52 21.54 21.56 21.58 0 2 4 Pm [dBr]